PRELUDE
In the past, many files have been written about COSMOS. I have always
been rather disappointed in their quality and in their presentation, so
I have taken on the responsibility of doing one myself. This should sum
up COSMOS for everyone who reads it. It contains formats for very useful
commands, an entire transaction list, COSMOS "tricks", and a list of all
COSMOS abbreviations and their formats.
INTRODUCTION
Bell Labs COmputer System for Mainframe OperationS (COSMOS) is basically
just a database for maintaining records of equipment and other line information
and generating reports on that information. The system is usually set up
on a DEC PDP 11/45 or 11/70.
The main responsibilities of the COSMOS system are:
Maintaining records Issuing reports Processing service and work orders Assigning telephone numbers Load balancing for switching computers Output of ESS recent change informationLOGGING ON
ROOT System Manager SYS System Manager ML Loop Assignment LA Loop Assignment DN Main Distributing Frame IN Repair Service RS Repair Service CE LNAC LK Account to execute INQuiries only JA Mizar WLI Work Load IndicatorUsernames may vary from BOC to BOC, but these are fairly standard.
BL Bridge Lifter CON Concentrator CP Cable Pair CKID Circuit ID MR Message Register OE Office Equipment Number PL Private Line Circuit Number TK Trunk Cable and Pair Number TN Telephone Number TP Tie Pair XN "X" Number TRE Transmission Equipment TER Terminal Number GP Group Number ORD Work OrderEX: To print information on telephone number 222-2222 WC% INQ
ST AU DATE 06-03-83 HT GP 0-0081 BTN 225-8004 TYPE X OE 006-012-200
ST WK DATE 03-04-86 CS 1FBH US 1BH FEA TNNL LCC TF2 LOC WF12003 TER 0-0081-0001 ST WK RMKG GTE.TELENET CP 95-0701 ST WK DATE 01-24-86 RZ 13 LOC WF12009 TP 6105-0910 ST WK DATE 01-24-86 LOC F12003 LOC F42001 FROM FAC OE 006-012-200 TO FAC TP 6206-0107 TP 6206-0107 ST WK DATE 01-24-86 LOC F22029 LOC F42002HUNT SEQUENCE FOR TN 225-8004
AU Auxiliary NP Non-published OF Official (telco owned) TS TestAnother way to distinguish types of number is by CS (Customer Class of Service). CS values tend to vary from BOC to BOC, but business lines will usually look like "1FB", or at least contain a "B". Residences will usually look like "1FR." Sometimes telco lines are listed as "1OF", but may also be entered as "1FB". On lines in a hunt group, the CS will be appended with the letter "H", as "1FBH". Let's say a company owns a block on an exchange (333) running from 1000 to 3500. You want to find all possible computer numbers in that area. Chances are good that they are not listed.
_I CCF XXXXXX (XXXXXX is valid custom calling features) _I BTN NNX-XXXX (NNX-XXXX is valid billing TN) _I TT CTo get a list of spare (available) telephone numbers in a given prefix, you can use the NAI (Telephone Number Assignment Inquiry) command. You only need enter H line criteria. In addition to searching by prefix (NNX), you can search by switch type (TYP), or rate zone (RTZ). EX: To select one spare telephone number in 555 and make it reserved status WC% NAI
/USR/FACS/WCFILE List of all Wire Centers /ETC/MATRIX.P Permission Matrix (Who can execute what commands)You may or may not want to try the following. There is a high probability that you will be noticed on the system. If your local COSMOS ports are usually left logged in, don't bother doing this. However, if your COSMOS ports are always logged out, and you almost never get in, and you happen to stumble upon one left logged for the first time in months, it might be worth a try.
AC XXXX PERM=Permanent Facility Assemblies TEMP=Temporary Facility Assemblies AC Assembly Code AC XXX XXX=1-999 ADSR Administration of Designed Services Review ADSR X Y=Yes, TIRKS Circuit N=No, COSMOS Circuit AGM Normal Aging Months AGM XX XX=Number of Months AGT Accelerated Aging Type AGT XXX BUS=Business RES=Residential AI Assigner's Initials AI XXX XXX=3 Alphanumeric Characters AO Allocation Order AO XX XX=Two Numeric Characters AR Advance Relay AR XYY-ZZZ X=Marker Group YY=Number Group from Frame ZZZ=Relay Number ATN Assigner's Telephone Number ATN XXX-XXXX XXX-XXXX=Assigners TN BL Bridge Lifter BL XX...XX XX...XX=Maximum of 17 Alphanumeric Characters BLS Bridge Lifter Status BLS X Y=Yes N=No BND Band Number BND X X=0-3 BTN Billing Telephone Number BTN XXX-XXXX XXX-XXXX=Billing Telephone Number CA Cable Number CA XX...XX XX...XX=Maximum of 10 Alphanumeric Characters CAT Centrex Access Treatment CAT XX XX=Maximum of 2 Numeric Characters CC Call Count CC XX XX=Maximum of 2 Numeric Characters CCF Custom Calling Features CCF XXXXXX XXXXXX=3 to 6 Alphanumeric Characters CCS Hundred Call Seconds CCS XXXX XXXX=3 or 4 Numeric Characters CEU CCS Estimated Usage CEU XXXX XXXX=3 or 4 Numeric Characters CG Control Group Number CG X X=0-9 CKID Circuit Identification CKID XX...XX XX..XX=Maximum of 61 Alphanumeric Characters CKL Circuit Location CKL XXXX XXXX=Maximum of 4 Alphanumeric Characters CLC Common Language Code for an Entity CLC XX...XX XX...XX=Maximum of 11 Alphanumeric Characters CLCI Common Language Circuit Identification CLCI XX...XX XX...XX=Maximum of 61 Alphanumeric Characters CLEI Common Language Equipment Identifier CLEI XX...XX XX...XX=Maximum of 10 Alphanumeric Characters CLF Creating DIPs Upper Bound Load Factor CLF XX XX=1-10 CLL Creating DIPs Lower Bound Load Factor CLF X X=1-9 CLS CLCI in Serial Number Format CLS XX...XX XX..XX=Maximum of 61 Alphanumeric Characters CLT CLCI Telephone Number Format CLT XX...XX XX...XX=Maximum of 61 Alphanumeric Characters CMF Capacity Main Station Fill CMF XXXXXX XXXXXX=Maximum of 6 Numeric Characters CMU CCS Measured Usage CMU XXXX XXXX=3 or 4 Numeric Characters COM Complement Size COM XXXX XXXX=1-9999 CON Concentrator CON XX-YY XX=Maximum of 2 Alphanumeric Characters YY=Maximum of 2 Numeric Characters CP Cable and Pair Number CP XX...XX-YZZZ XX...XX=Cable ID, Maximum of 10 Alphanumeric Characters YZZZ=Cable Pair ID Y=Alphanumeric ZZZ=Numeric CPU CCS Capacity Usage CPU XXXX XXXX=3 or 4 Numeric Characters CRG CREG Tag CRG XXX XXX=YES or NO CS Customer Class of Service CS XXXXXX XXXXXX=Maximum of 6 Alphanumeric Characters CTID Circuit Termination Identification CTID XX...XX XX...XX=Maximum of 61 Alphanumeric Characters CTT Cut Through Tag CTT XXX XXX=YES or NO CTX Centrex Group Number CTX XXXX XXXX=Maximum of 4 numeric Characters DC Dial Code DC X X=1 Alpha Characters DD Due Date DD MM-DD-YY MM=Month DD=Day YY=Year DID Direct Inward Dialing DID XXXX XXXX=Maximum of 4 Numeric Characters DIP DIP Creation Option DIP X Y=Yes N=No DNY Denial of Service for Non-payments DNY X I=Incoming O=Outgoing B=Both DPA Different Premises Address DPA XXX XXX=Maximum of 3 Alphanumeric Characters DPT Department Name DPT XXX XXX=Maximum of 3 Alphanumeric Characters DST Destination of Order Response DST XXXX XXXX=Maximum of 4 Alphanumeric Characters DT Due Time DT XX XX=AM, PM, or 0-9 EC ESS Entity and Control Group Number EC YZ Y=Entity Number Z=Control Group Identifier ECS Equipment Class of Service ECS XXXXXX XXXXXX=Maximum of 6 Alphanumeric Characters ED Enter Date ED MM-DD-YY MM=Month DD=Day YY=Year EN Entity EN X X=S, E, 1, 5 or 0 EN Entity Number EN X X=0-9 ENT Entity Number ENT X X=0-9 EO Error Handling Option EO XX CE=Continue Processing and Establish Valid Circuits CW=Continue Processing and Withdraw Established Circuits SE=Stop Processing and Establish Valid Circuits SW=Stop Processing and Withdraw Established Circuits EQF Equipment Features EQF WXYZ W=R (Rotary) or T (Touchtone) Y=S (Sleeve) X (Range Extension) or N (Non-sleeve or Non-range Extension) X=E (Essential) or N (Non-essential) Z=G (Ground Start) or L (Loop Start) EQV Frame Equivalence EQV FXX F=The Letter "F" XX=Two Alphanumeric Characters ETC Estimated Trunk CCS Value ETC XXXX XXXX=Maximum of 4 Alphanumeric Characters EXD ECS Crossloading Option EXD XXX XXX=YES or NO FAC Type of Segment List Being Audited FAC XX TN=Telephone Number OE=Line Equipment FAC Circuit Confiruration FAC XXX or FAC TN-NNX or FAC CP-XX...X or FAC SE-YY...Y or FAC PL-ZZ...Z XXX=Any Facility Prefix NNX=Three Alphanumeric Characters XX...XX=Maximum of 10 Alphanumeric Characters YY...YY=Maximum of 52 Alphanumeric Characters ZZ...ZZ=Maximum of 61 Alphanumeric Characters FC From Cable FC XX...XX XX...XX=Maximum of 10 Alphanumeric Characters FDD Frame Due Date FDD MM-DD-YY MM=Month DD=Day YY=Year FEA Customer Feature FEA XXXX (Same as EQF) FILT Filter FILT XXX XXX=Y, YES, N, or NO FR Frame Identification FR FXX F=The letter "F" XX=Two Alphanumeric Characters FT Frame Time FT XX XX=01-24 FW MDF Output Suppressed FW X Y=Frame Work Yes N=Frame Work No GP MLHG Group Number GP Y-XXXX Y=Alphanumeric Control Group XXXX=Numeric Group Number GSO Ground Start Option GSO X 1=Assigned to any OE in the Entity 2=Assigned to Even Levels 3=Only Assigned to OE Specified as Ground Start HC Hunt Count HC XXXX XXXX=Maximum of 4 Numeric Characters HF Hunt-from Telephone Number HF XXX-XXXX XXX-XXXX=Telephone Number HLC Highest Lead Factor Group Count HLC XXXX XXXX=1-9999 HR Held Order Reason Code HR XX CE=Equipment Shortage CF=Lack of Facility CL=Plant Load CO=General Company Reasons C1-C5-Additional Company Reasons SA=Subscriber Access SL=Subscriber Requested Later Date SO=General Subscriber Reasons SR=Subscriber Not Ready S1-S5=Additional General Subscriber Reasons HRS Hours Prefix HRS XX XX=01-24 HT Hunt-to Telephone Number HT XXX-XXXX XXX-XXXX=Telephone Number HTG Hunt-to Group Number HTG Y-XXXX Y=Alphanumeric Control Group XXXX=Numeric Group Number HTX Hunt-to X Number HTX XXX-YYXX of HTX XXX-YXX Y=Alphanumeric X=Numeric INIT Allocation Table Initalization INIT (No Data Entry) ITM Cable Pair Item Number ITM XX XX=Two Numeric Characters JL Jumper Length JL XXX XXX=Maximum of 3 Numeric Characters JR Jeopardy Reason JR XX A1=Assignment Error on CP A2=Assignment Error on OE A3=Assignment Error on TN A4-A9=Other Assignment Error C1=No SSWO for Circuit Design Group C2-C9=Local Code for Circuit Design Group E1-E9=No ESS Translations IB=No Installation Go-ahead for Business IC=No Installation Go-ahead for Coin ID=No Installation Go-ahead for Data IR=No Installation Go-ahead for Residence IS-No Installation Go-ahead for Special I1-I4=Local Codes foir No Installation Go-ahead RB=Business RSB RC=Coin RSB RD=Data RSB RR=Residence RSB RS=Special RSB R1-R4=Local Use for RSB LC Output Line Count LC XXXX XXXX=0-9999 LC Line Count LC XXX XXX=0-999 LC Pending Service Order Count LC (No Data Entry) LCC Line Class Code LCC XXX XXX Maximum of 3 Alphanumeric Characters LD Loading Division LD XX XX=Two Numeric Characters LDN Listed Directory Number LDN XXX-XXXX XXX-XXXX=Telephone Number LF Load Factor LF XX XX=1-10 LIM Less Than the Specified Number of Pairs LIM XX XX=0-50 LIM High Limit on Number of Specified Status Pairs in a Complement LIM XX XX=0-50 LIM Low Limit on Number of Spare Line Equipment in Vertical Files LIM XX LIM=1-10 LLC Low Load Group Count LLC XXXX XXXX=0-9999 LOC Location LOC FXXYYY F=The Letter "F" XX=Alphanumeric YYY=001-999 LP Loop Range LP XXX;XXX XXX;XXX=Six Numeric Characters LS List New Pending Cable Transfers LS XXX XXX=NEW LTI Loop Termination Identifier LTI XXX XXX=Three Alphanumeric Characters MASK Office Equipment Mask MASK OE ID ID=XXX-XXX-XXX =1ESS ID=XXX-XXXX =2ESS ID=XXX-XXXX =3ESS ID=XXXX-XXX-XX =5ESS ID=XXXX-XX-XX =5ESS ID=XXXX-X-XXXX =RSS ID=XXXX-XXX-XX =1XB ID=XXXX-XXXX-XX =1XB ID=XXX-XX-XX =5XB ID=XXXX-XXX =SXS ID=XXX-X-XX-X =DMS-10 ID=XXX-X-XX-XX -DMS-100 X=Alphanumeric MAT Manual Assistance Tag MAT XXX XXX=YES or NO MAX Maximum Percentage Value of Entity Fill or Maximum CCS Value MAX XXX XXX=Maximum of 3 Numeric Characters MBL Mini-bridge Lifter Tag MBL XX Y=MBL Working on CP N=CP Can't Support MBL EQ=CP has MBL Capabilities MC Marker Class of Service MC XX XX=Two Alphanumeric Characters MF Recent Change Message Format MF XXXX NEW=RX:LINE:messages OUT=RC:LINE:OUT:messages CHG=RC:LINE:CHG:messages SUSP=RC:LINE:CHG:messages of suspended service MF Jumper Listing for MDF MF XXX NEW=Running Jumper Listing DJ=Dead Jumper Listing MF Message Format When Completing Transfer Circuits with TOC MF XXX ALL=Message is Printed for Every Circuit in Range ERR=Message Printed Only for Circuits not Completed MF Message Format for Dial Transfer Number Lists MF XXX GVR=Transaction GFR Output Format, One Facility per Line LVT=Line Verification Test Format TLC=Two-line Condensed Format MG Marker Group Number MG X X=0-9 MIN Minimum Percentage Value of Entity Fill or Minimum CCS Value MIN XXX XXX=Maximum of 3 Numeric Characters MLP Multi-loop Resistance Zone Threshold MLP XX XX=Two Numeric Characters MOD Module Number MOD XXX XXX=Three Numeric Characters MODE Integrated SLC No. 5ESS Mode MODE X 1=5 T1 Carrier Channels 2=3 T1 Carrier Channels MPN Master Work Package Number MPN XXXX XXXX=1-9999 MR Message Register MR XXXXXX XXXXXX=Maximum of 6 Alphanumeric Characters MRO Message Register Option MRO XXX XXX=YES or NO MT Master Record Tape Unit Number or Tape Drive to Write MT X X=Numeric MTR Tape Drive to Read MTR X X=Numeric MTW Tape Drive to Write MTW X X=Numeric NAR NAC Assignment Review NAR XXX XXX=Maximum of 3 Numeric Characters NGF Number Group Frame for 5XB NGF XXX XXX=Three Numeric Characters NNX Telephone Exchange Code NNX XXX XXX=THree Numeric Characters NOE Number of OEs to be Assigned NOE X X=0 or 1 NPA Area Code and Exchange Number NPA XXXXXX XXXXXX=Six Alphanumeric Characters NRM Normalizing CCS VAlue NRM XX XX=0-99 NTN Number of TNs to be Assigned NTN X X=0 or 1 OA Line Equipment Assignment Option OA X Y=Yes N=No OC Order Category OC XXX ACT=Assignment Change Ticket ALL=All OE Load Factors CPC=Special Service FM=Count Since OE Input Features Occurrences FO=Count All OE Input Feature Occurrences HOT=Frame Ouput-urgent JR=Jeopardy Reason OCS Old Class of Service OCS XXXXXX XXXXXX=Maximum of 6 Alphanumeric Characters OD Output Device OD XXXX TT=Send Output to Current Terminal TTXX=Send Output to Specified Terminal XX MTX=Send Output to Magnetic Tape X OE Office Equpiment Number OE ID (See MASK) OGO Outgoing Only Trunk OGO XXX XXX=Maximum of 4 Numeric Characters OPT Party Assignment Option OPT X 1=Assign Multi-party Customers to Spare Party Equipment 2=Assign Multi-party Customer to Partially Equipped Party Equipment 3=Assign Only One Multi-Party Customer to each Single Party Equipment ORD Service or Work Order ORD XX...XX XX...XX=Maximum of 20 Alphanumeric Characters OT Service or Work Order Type OT XXX BT=Background Transfer CD=Complete Disconnect CH=Changed CIO=Company Initiated Orders F="FROM" LET=Line Equipment Transfers LST=Line and Station Transfers MCE=Maintenance Change by LAC MCR=Maintenance Change by Repair MCT=All Maintenance Changes NC=New Connect R=Remarks REA=Pending Reassociation SW=Swap T="TO" PBX Private Branch Exchange PBX XXXX XXXX=Maximum of 4 Numeric Characters PCID Primary Circuit Identification PCID XX...XX XX...XX=Maximum of 61 Alphanumeric Characters PKT Picket Fence Values PKT XXX.X,...,XXX.X XXX.X,...,XXX.X=Nine sets of Four Numeric Characters or N=No New Values PL Private line Circuit Number PL XX...XX XX...XX=Maximum of 61 Alphanumeric Characters PNL PREMIS Number List for TN PNL XX...XX XX...XX=Maximum of 12 Alphanumeric Characters POP Line Equipment Print Option POP XXX CNC=Concentrator-1ESS, 2ESS, 3ESS, RSS CNG=Concentrator Group-2ESS, 3ESS HG=Horizontal Group-5XBAR IM=Interface Module-5ESS LFG=Line Finder Group-SXS LLF=Line Link Frame-5XBAR LLN=Line Link Net-1ESS LTN=Line Trunk Net-2ESS LU=Link Unit Module-5ESS QC=Quarter Choice-1XBAR SW=Switch-1XBAR VF=Vertical FIle-5XBAR PR Cable Pair ID PR YXXX Y=Alphanumeric XXX=Numeric PRI Frame Priority PRI XX XX=Two Numeric Characters PRP Permanent Cable Pair Remarks PRP XX...XX XX...XX=Maximum of 14 Alphanumeric Characters PRZ Preferred Rate Zone PRT X X=Numeric PS Previously Published/Non-published Facility Indicator PS X N=Non-Published !=Published PT Package Time PT XXX XXX=Three Numeric Characters PTY Party Number or Position PTY X X=1-4 PTY Party Indicator PTY X R=Reserved O=Open PWC PREMIS Wire Center PWC XX...XX XX...XX=Maximum of 8 Alphanumeric Characters PWC Print Work Code PWC XXX NBT=No Back Tap COM=Frame Complete PBT=Print Back Tap RCT=Place Heat Coils on "TO" Pair RBT=Remove Back Tap RCF=Remove Heat Coils on "FROM" Pair VBT=Verify Back Tap USX=Locally Defined Codes (X=1-4) RAP Rotary Assignment Priority RAP X X=Numeric RCT Recent Change Type RCT XX 1=1ESS Office 1A=1AESS Office 2=2ESS (LO1) 2E=2ESS (EF1 and EF2) 3=3ESS 5T=5ESS RCW Recent Change Keyword RCW XX...XX XX...XX=Maximum of 20 Alphanumeric Characters RD Release Date RD MM-DD-YY MM=Month DD=Day YY=Year RDG Message Register Reading RDG XXXX XXXX=Four Numeric Characters REC Record File Name and Number REC FFXXXXXX FF=File Name (Alphanumeric) XXXXXX=Record Number (Maximum of 6 Numeric Characters) REP Reprint Option REP X Y=Yes N=No RESP Send a Solicited Response RESP X S=Solicited Response REW Rework Status REW X Y=Yes N=No RLF Re-using DIPs Upper Bound Load Factor RLF X X=1-9 RLO Automatic Relay Assignment Present RLO X Y=Yes N=No RLY Miscellaneous Relay RLY XX...XX XX...XX=Maximum of 10 Alphanumeric Characters RMK Remarks on Orders RMK XX...XX XX...XX=Maximum of 28 Alphanumeric Characters RMKG Hunt Group Remarks RMKG XX...XX XX...XX=Maximum of 30 Alphanumeric Characters RMKO Remarks on Office Equipment RMKO XX...XX XX...XX=Maximum of 12 Alphanumeric Characters RMKP Remarks on Cable Pair RMKP XX...XX XX...XX=Maximum of 14 Alphanumeric Characters RMKT Remarks on Telephone Number RMKT XX...XX XX...XX=Maximum of 14 Alphanumeric Characters RNO RSS Subentity Number RNO XX XX=01-63 RTI Route Index RTI XXXX XXXX=Maximum of 4 Numeric Characters RTYP Relay Type RTYP XXX TBA=Tens Block Auxiliary SC=Sleeve Connect AR=Advance RTZ Rate Zone RTZ X X=Numeric RW Recent Change Work RW X N=Recent Change Message not Required C=Recent Change Coordination Required RZ Resistance Zone RZ XX XX=Two Numeric Characters SBS Sub-status SBS X A=Area Transfer C=Cut Through D=Dedicated L=Cut Through and Dedicated !=Blank SC Sleeve Connect Relay SC SYY-ZZZ S=Marker Group (Numeric) YY=Number Group Frame (Numeric) ZZZ=Relay Number (Numeric) SE Special Service Equipment Number SE XX...XX XX...XX=Maximum of 52 Alphanumeric Characters SET Single Entity Tag SET X Y=CP is Served by a Single Entity on a Single Frame !=CP Can be Served by More Than One Entity SG Service Segment SG X B=Business C=Coin D=Data R=Residence S=Special SGN Common Language Segment Number SGN XXX XXX=Maximum of 3 Alphanumeric Characters SIS Special Identifying Telephone Number Supplement SIS XXXX XXXX=Maximum of 4 Numeric Characters SIT Special Identifying Telephone Number SIT XXX-YYY-XXXX X=Numeric Y=Numeric SK Skip Option SK X X=0 or 2-9 SN Sequence Number SN XXX XXX=1-999 SOB Service Observing Tag SOB XXX XXX=YES or NO SS Suspension Status SS XX DB=Deny Both Ways DI=Deny Incoming DO=Deny Outgoing RS=Restore Suspended Circuit SB=Suspend Both Ways SD=Season Disconnect SI=Suspend Incoming SO=Suspend Outgoing DX=Deny Toll Access Tervice SSV Suspend Service Type SSV XX DO=Deny Outward Service DB=Deny Both Outward and Inward Service DX=Deny Toll Access Service RS=Restore Denied Service STAT Order Status STAT XX AC=Pending With no Framd or Installation Completion FC=Pending With Frame Completion but no Installation Completion IC=Pending with Installation Complation but no Frame Completion CC=Completed Orders CA=Canceled Orders STAT Facility Status STAT XX AS=All Spare EX=Excluded PC=Pending Connect RS=Reserved SF=Spare Facility UK=Unknown WK=Working STAT Load Group Status STAT XX EX=Blocked from all Assignments FU=Open for Dial Transfer Assignments Only PS=Pseudo LEN Assignments Only SO=Open for Service Orders and Work Orders Only WK=Open for All Assignments STO Line Equipment Status STO XX AW=All Working MS=Miscellaneous OF=Official TJ=Trunk and Junctor TS=Test WK=Working PD=Pending Disconnect PK Pending Disconnect/Pending New Connect AS=All Spare EX=Excluded LI=Left-in Disconnect RS=Reserved SF=Spare UK=Unknown PC=Pending Connect STP Cable and Pair Status STP XX AL=All Pairs AD=All Defective AP=All Provisioned AW=All Working DC=Designed Circuit DI=Defective (I=1-9) DM=Designed + SSM DP=Designed + SSP SM=Special Safeguard Measures SP=Special Safeguard Protection SS=Special Status WK=Working AS=All Spare EX=Excluded LI=Left-in Disconnect RS=Reserved SF=Spare UK=Unknown PC=Pending Connect PD=Pending Disconnect STT Telephone Number Status STT XX AU=Auxiliary AW=All Working MS=Miscellaneous NP=Non-published OF=Official TJ=Trunk and Junctor TS=Test WK=Working AS=All Spare AV=Available CM=Changed-Machine Intercept CO=Changed-Operator Intercept DM=Disconnected-Machine Intercept DO=Disconnected-Operator Intercept EX=Excluded RS=Reserved SF=Spare UK=Unknown PC=Pending Connect PD=Pending Disconnect PK=Pending Disconnect/Pending New Connect SUBL Sublet Service SUBL XXX-XXXX XXX-XXXX=Telephone Number SWC Set Work Code SWC XXX (See Print Work Code) SWG Switch Group SWG X X=0-2 SYS Machine Number SYS XX...XX XX...XX=Maximum of 12 Alphanumeric Characters TA Transfer Assembly TA X Y=Yes N=No TAP Touchtone Assignment Priority Number TAP X X=Numeric TBA TBA Relay TBA XYY-ZZZ X=Marker Group Number (Numeric) YY=Number Group Frame (Numeric) ZZZ=Relay Number (Numeric) TBS TBS Relay TBS XZ-NN X=Marker Group Number (0-9) Z=Relay Number (0-3) NN=Ringing Combination (01-16) TC TO Cable TX XX...XX XX...XX=Maximum of 10 Alphanumeric Characters TER Terminal TER XXXX XXXX=Maximum of 4 Numeric Characters TER Terminal Number TER Y-XXXX-ZZZZ Y=Control Group (Alphanumeric) XXXX=Group Number (Numeric) ZZZZ=Terminal Number (Numeric) THG Thousands Group THG X or THG XXXX X=0-9 XXXX=0000,1000,...,9000 TK Trunk Cable and Pair Number TK YYYYYY-XXXX YYYYYY=Cable ID (Maximum of 6 Alphanumeric Characters) XXXX=Cable Pair ID (Maximum of 4 Numeric Characters) TLI Telephone Line Identifier TLI XXX-YYY-XXXX X=Numeric Y=Alphanumeric TN Telephone Number TN XXX-XXXX XXX-XXXX=Telephone Number TOM Two or More Non-pending, Non-party Filtered Circuit Facilities TOM XX CP=Cable Pair TN=Telephone Number OE=Office Equipment TP Tie Pair TP YY...YY-XXXX YY...YY=Cable ID (Maximum of 10 Alphanumeric Characters) XXXX=Tie Pair ID (Maximum of 4 Numeric Characters) TPR Taper Code TPR XXXXXX XXXXXX=Maximum of 6 Alphanumeric Characters TRE Transmission Equipment TRE XX...XX XX...XX=Maximum of 17 Alphanumeric Characters TT Telephone Number Type TT X B=POTs Hunting C=Coin G=Complex Service (Direct Inward Dialing, Radio Common Carrier, etc) O=Official Q=Centrex X=POTx Non-hunting TTA Terminating Traffic Area TTA XXX XXX=Maximum of 3 Alphanumeric Characters TYP Switching Type TYP XXX 1ES=Number 1ESS 2ES=Number 2ESS 3ES=Number 3ESS 5ES=Number 5ESS RSS=Remote Switching System 1XB=Number 1 Cross-bar 5XB=Number 5 Cross-bar SXS=Step-by-step DMX=DMS-10 DMC=DMS-100 US USOC US XXXXX XXXXX=Maximum of 5 Alphanumeric Characters USE Entity Usage USE X G=Growth S=Stable VAL Minimum Valid Hours for Entity Data VAL XX XX=1-99 WC Wire Center WC XX XX=Alphanumeric WL Work Location WL Y Y=1-8 or WL XXX ADM=Administrative ACT=Assignment Change Ticket CPC=Special Service Circuits MCT=Maintenance Change Tickets WPN Work Package Number WPN XXXX XXXX=1-9999 WPT Work Package Type WPT XXX XXX=Maximum of 3 Alphanumeric Characters XN "X" Number XN XXX-YYXX or XN XXX-YXX X=Numeric Y=Alphanumeric ZN Zone Location ZN XXX XXX=001-999